In memory of Roberto Gandini, founder and Chairman of InjectionPower. Read more
Skip to Content


Find tools and test equipment for your diesel workshop

See prices after sign-in. Not sure? Download the catalog or request a quote.

Optional equipment

Adapter cable
Adapter cable for Zexel Covec F application on HYUNDAI 104700-9071
Adapter cable for Zexel Covec F pumps
Adapter cable for Zexel Covec F pumps application on Hyundai H100 ( 407980-2670) - 15 poles
Adapter cable for Zexel Covec-F
Adapter cable for Zexel Covec-F pumps application on ISUZU 4JG2 engines
Adapter cable for Zexel Covec-F pumps
Adapter cable for Zexel Covec-F pumps application on HYUNDAI (MITSUBISHI) engines ( L200 4D56 engines)
Adapter cable for Zexel Covec-F pumps
Adapter cable for Zexel Covec-F pumps application on MAZDA engines
Cable adapter for Zexel Covec-F pumps
Cable adapter for Zexel Covec-F pumps application on NISSAN TD27, CD20 engines
DETEQ 81.21.090 OTA Electrical Diagnostic Interface
OTA electrical diagnostic interface for diesel injection pump sensors and actuators. Connect the same application adapter cable used for bench testing, leave the multimeter probes fixed in OTA, and use the two rotary selectors to create the required contact combinations. Fixed measuring points and gold-plated contacts make resistance, continuity and short-circuit checks simpler, faster and more reliable. Function comparable to Bosch 0 986 611 929.
Elektronikus előtoldat-érzékelő
Elektronikusan méri a forgódugattyús dízelszivattyúk előtoló dugattyújának elmozdulását, lehetővé téve a DETEQ vezérlőegységeken keresztüli pontos időzítés-ellenőrzést és kalibrálást.
MM - Multimeter
MM - Palmar multimeter for EDC tests
Training service
Training service for the use of the ERT45R Simulator with the kits for the test of ZEXEL Covec F1/F2 pumps with electric actuator. This is not a full training concerning the complete overhault of this pump.
The matters of this training are the following:
- Performance features of the products
- Details and installation problems
- Methods of use
- Maintenance
- Practice with the help of DETEQ technicians. The participants will be first instructed and then followed step by step by our technical personnel for practical exercises.
- Location: in Italy at DETEQ headquarter
- Duration: 1 day (8 working hours)
- Maximum number of attenders: 2 diesel specialists having skills on this type of pump
- Is held in English Language
- Individual Certificate of Training is delivered.
VTR110 Digital Thermometer and Fuel Cooling Device.
Measures pump outlet fuel temperature and allows the pump control valve to be bypassed for faster fuel cooling during testing.